LEPU PC-60FW High Accurate Bluetooth Blood Oxygen Monitors SpO2 Finger Pulse Oximeter With APP Analysis Result
The fingertip pulse oximeter is intended for measuring the Pulse Oxygen Saturation, Pulse Rate, and Perfusion Index through user’s finger. Lepu Medical focuses on R&D and manufacturing for more than 23 years. The self-developed MoveOxy technology provides professional measurement results against motional affect, low PI, and weak pulse signal conditions.
Feature of LEPU PC-60FW High Accurate Bluetooth Blood Oxygen Monitors SpO2 Finger Pulse Oximeter With APP Analysis Result
Fingertip design – light and compact, dual-color display, 360°visual, 4 direction switching
User data storage – 12 group of storage data, menu setting function.
Dual measurement modes, easy to detect – Support 30 seconds Spot-check measurement and continuous measurement.
Humanized design – Invisible wire design, prevent leakage electric shock
Bluetooth function – Wireless Module with APP for real-time display, Pulse rate analysis on spot check mode
Alarm function – Measuring over limit alarm, Audible and visual alarm with low battery indication
Voice broadcast for measurement results, convenient for children and the elderly to use at any time.
App data management – PC-60FW supports small programs, APP, WeChat links to share data, record your health information, remote control, and achieve intelligent health management
Automatic analysis intelligentscreening – 12 kinds of abnormal heart rhythm analysis, heart problems can be known within 30 seconds
Automatic induction switch – The data will be automatically displayed within 8 seconds after the finger is put in, and it will automatically shut down if there is no finger sensing within 1 minute.
LEPU CREATIVE’s unique anti-motion algorithm – anti-shake, anti-drop, applicable to a variety of scenarios.
Product Parameters of LEPU PC-60FW High Accurate Bluetooth Blood Oxygen Monitors SpO2 Finger Pulse Oximeter With APP Analysis Result
Item
PC-60FW
PC-60F
Bluetooth
Wireless, with bluetooth function
NO Bluetooth
SpO2
Transducer
Dual-wavelength LED sensor
Measuring range
35%~100%
Measuring accuracy
≤ 2% range from 70% to 100%
Pulse Rate
Measuring range
30bpm~240bpm
Measuring accuracy
±2bpm or ±2% whichever is greater
Perfusion Index (PI)
Display range
0%~20%
Default Alarm Limit
Spo2 low limit
90%
Pulse Rate
High limit: 120bpm
Low limit: 50bpm
Power supply
2 x AAA alkaline battery
Supply voltage: 3.0V DC
Operating current: ≤40mA
Dimension
56 mm (L) × 34 mm (W) × 30 mm (H)
Net Weight
52g
Measuring Mode
30 seconds Spot check and Continuous mode
Pulse Rate Analysis(Spot check mode)
12 types preset analysis
Data Storage
Up to 12 groups.